3.4 OPTIONAL AC DISCONNECT SWITCH INSTALLATION: Connect disconnect switch in

line with VAC line (black wire) (see Figure 13).




Figure 3.1







Figure 13 Figure 14

3.5 Finish power supply AC connection by connecting black VAC line to black input cord of

power supply, and white neutral to white input cord of power supply. Connect green
ground wire from line to the same metal surface the power supply is mounted on (see
Figure 14).

3.6 Power Supply Information:

Table 1

– Power Supply Information

Item

Number

Ordering Description

Power

Supply

Wattage

Input

Voltage

(VAC)

Input

Current

(A)

Output

Voltage

(V)

51514

OT75W/24V/UNV

75W

120/277

0.76/0.33

24

51522

OT96W/12V/UNV

96W

120/277

0.97/0.39

24


Table 2

– Max. Number of Modules per Power Supply





Item Number

Ordering Abbreviation

Max. Modules per

Power Supply

51514

OT75W/24V/UNV

13

51522

OT96W/12V/UNV

17

Optional

Disconnect

Switch

VAC out from

Disconnect Switch

VAC into Disconnect Switch