Mesur-fil fluid couplings, Slip curves – Wichita Clutch Fluid Coupling User Manual

Page 12

Advertising
background image

C

Mesur-Fil Fluid Couplings

P-1100-WC 1/12

Wichita Clutch 800-964-3262 165

G

Selection Example:

7.5 HP at 1,750 RPM

Normal running torque =

7.5 HP * 5,250 = 22.5 lb.ft.

1,750

Pullout torque is obtained at approximately
85% full motor speed and for NEMA B motors,
this is approximately 200% normal rated
torque.

If the pullout torque is unknown, then assume
200% of normal rating occuring at a speed
of 1,540 RPM, with full motor speed of
1,750 RPM.

Pullout torque = 2 * 22.5 lb.ft. = 45 lb.ft.

Locate the pullout torque against RPM curve
to insure the point is slightly above the drag
torque line.

Locate the normal torque against RPM curve
to insure the point is below the 7% slip line.
Ideally, plot the point between 3% and 5%
slip line.

Slip Curves

Size 15

Maximum speed 2,600 RPM (All configurations)

Advertising