Venting runs, Radiance direct vent /natural vent gas heater, Termination clearances – Vermont Casting RDVOD 3369 User Manual

Page 11: Venting requirements - natural vent only

Advertising
background image

11

Radiance Direct Vent /Natural Vent Gas Heater

20004188

�����
����������������������
��������

Venting Runs

Horizontal Run (in feet)

Vertical Run (in feet)

(Measured from top of the unit before any elbow)

A: Vertical installations up to 36 feet (12m) in

height. Up to an 18 ft. horizontal vent run can be

installed within the vent system using a

maximum of two 90-degree elbows or four

45-degree elbows.

B: Vertical installations up to 36 feet (12m) in

height. Up to a 24 ft. horizontal vent run can be

installed within the vent system using a

maximum of two 45-degree elbows.

(Ratio = 2/3, Hor./Vert.)

= Acceptable venting configuration
= Unacceptable venting configuration

��
��
��
��
��
��
��
��
��
��
��
��
��
��




������������������������������������������������������

A

B

NOTE: When venting staight vertical, without any

elbow, a minimum of 8 ft. vertical is required

off the top of the stove.

Outside Corner

Inside Corner

Termination Clearances

Termination clearances for buildings with combustible and noncombustible exteriors.

A =

Combustible

6"(152mm)
Noncombustible

2"(50mm)

B =

Combustible

6"(152mm)
Noncombustible

2"(50mm)

A

Balcony -

with no side wall

G =

Combustible &

Noncombustible

12"(305mm)

G

Balcony -

with perpendicular side wall

H = 24"(610mm)
J = 20"(508mm)

H

J

B

Recessed Location

C = Maximum depth of 48"

(1219mm) for recessed

location.

D = Minimum width for back wall

of a recessed location.

Combustible 38"(965mm)

Noncombustible 24"(610mm)
E = Clearance from corner in

recessed location.

Combustible 6"(152mm)

Noncombustible 2"(50mm)

C

D

C

E

V

V

Combustible &

Noncombustible

V

V

V

584-15

Fig. 10 Termination clearances.

Venting Requirements - Natural Vent Only

Fig. 11 Vent termination window - Natural Vent ONLY.

NOTE: When using the FSDHAG, the restrictor

plate supplied with the stove is not used.

Advertising