Rheostat

Retaining Collar

Rheostat Knob

ST347a

Fig. 17 Attach the fan rheostat.

Rheostat

Install the Optional Fan

If you are installing the optional convection Fan Kit

#2767 (FK26), continue here. It is easiest to install fan

kit before connecting gas line. If you are not installing a

Fan Kit, go to Page 15, Venting System Assembly.
1. The fan kit includes a Blower Assembly and a Rheo-

stat Assembly, connected by a cable. (Fig. 14) The
Blower Assembly mounts to the bottom rear of the
stove, and the Rheostat mounts to the valve cover-
plate. The assembly includes a ‘snapstat’ which au-
tomatically turns the fan On (or Off) above (or below)
approximately 109˚. The Rheostat also provides a
range of fan speed settings from Off (which overrides
the snapstat function) to High. Unpack and inspect
the Blower assembly. Confirm that the fan spins
freely.

ST147

RDV40 remove rear shroud

10/99

Fig. 15 Remove rear shroud.

ST147

ST473

Fan parts

#2767 FK26

9/29/00

Not

Used On

Radiance

Snapstat

Bracket

Snapstat/

Extension

Assembly

Rheostat

Assembly

ST473

Blower

Assembly

Fig. 14 Fan kit components.

Not Used On

RF Models

Not Used

On RF

Models

Connect to PC board on

RF models only

WARNING

This appliance is equipped with a three-prong
(grounded) plug for your protection against shock
hazard and should be plugged directly into a
properly grounded three-prong receptacle. Do not
cut or remove the grounding prong from this plug.

2. Remove the rear shroud panel (Fig. 15) and fasten

the blower assembly to the firebox back with the two
bolts provided. (Fig. 16)

NOTE: Steps 3 and 4 do not apply when the RF valve

is used. After attaching blower assembly to the fire-
box, run the spliced female leads to the front of the
stove and attach to back of RF valve. (Page 30, Fig.
57)

3. Attach the snapstat assembly to the snapstat bracket

with two sheet-metal screws. Attach the snapstat
bracket to the side shield. (Fig. 16)

4. The rheostat control switch attaches to the left side

of the valve bracket at the front of the stove. (Fig. 17)

ST149

rdv attach fan assy

10/99

Side Shield

Snapstat

Bolts

ST149

Fig. 16 Attach blower assembly and snapstat.

Remove the plug from the rheostat bracket.

Insert the switch box shaft through the hole in the

back of the right side of the valve bracket, aligning
the locator pin with the smaller hole in that bracket.

Attach the control knob to the rheostat shaft.

Use the wire tie to secure the fan and rheostat wire

harnesses together.