Monarch Instrument ACT-1B Series User Manual

Page 5

Advertising
background image

2

Installation

Remove the mounting clips, if fitted, and install the unit into the panel from
the front. From the rear of the unit, install the mounting clips on each side
and tighten the mounting screws against the rear of the panel.

WARNING:

Do not over tighten the mounting screws.

Power

Power to the unit is connected to the terminals under the section labeled
POWER on the rear panel. Be sure the power supplied matches the
specification indicated on the rear panel. Refer to Figure 2 below.

Figure 2 ACT-1B Rear Panel

If the unit is ac powered (100 - 240 Vac), connect the Live (Hot) wire to
the terminal marked L+ and the Neutral (Return) wire to the terminal
marked N-.

If the unit is dc powered, connect the dc supply Positive to the terminal
marked L+ and the dc supply Negative or Common to the terminal
marked N-.

USB
Programming
Jack

9

ACCESSORIES / SENSORS

T-5

Reflective Tape - 5 foot (1.5 m) roll, 0.5 inch (10 mm) wide

USB Programming Cable with PM Remote Software on CD:

Enables the user to program the ACT-1B using a PC with
USB connection. The software also allows remote monitoring
of the RPM using a graphic display or an Excel

TM

spreadsheet.

ROLS-W

Remote Optical Laser Sensor with 8 foot cable

ROS-W

Remote Optical Sensor with 8 foot cable

ROS-P-25

Remote Optical Sensor with 25 foot cable (must cut plug off)

ROS-HT-W-25

Remote Optical Sensor for high temperature applications
to 257 °F (125 °C) with 25 foot cable

P5-11

Proximity Sensor

M-190W

Magnetic Sensor with 8 foot cable

MT-190W

Magnetic Trigger Sensor with Amplifier Module, 8 foot cable

GE-200

Gasoline Engine Electromagnetic Inductive Sensor and
amplifier with 23 feet of cable

IRS-W

Infrared Sensor with 8 foot cable