Monarch Instrument ACT-3 User Manual

Page 6

Advertising
background image

1

1.0

GENERAL OVERVIEW

The ACT-2A / ACT-3A / ACT-3 digital panel meters are extremely versatile instruments. The user has
complete control of the unit configuration. Power may be either 115 Vac or 230 Vac (50/60 Hz), or
optionally, 12 Vdc to 15 Vdc. Input signals are accepted from optical, proximity, magnetic, infrared or
laser sensors, or direct TTL or external AC sources. All models are suitable for panel mounting or
bench top, with convenient screw terminal connections on the rear panel of the instrument.

When the instrument is turned on, it displays all 8s, then rEvx.x, where x.x is the software revision
level, before entering the normal mode of operation. The display will show “——- “ when a measurement
is over range.

1.1

Modes of Operation

There are a number of different modes of operation. These modes determine what is shown on the
display for any given input to the instrument. Basically, it determines what computation is
performed on the input. Refer to Section 6.0 for details on changing modes.

NOTE: The instrument is programmed from the factory in the RPM Mode for one pulse per

revolution.

1.1.1

RPM Mode

In the RPM Mode the unit behaves like a tachometer displaying revolutions (revs) per
minute (RPM) from an input of 1 pulse per revolution. The instrument effectively multiplies
the input frequency (pulses per second) by sixty to derive RPM. In this mode, the range of
the unit is 5 to 999,990 RPM. The RPM LED on the bottom right of the display area
illuminates to indicate the RPM mode is programmed.

NOTE: For applications with more than one pulse per revolution, the Scaling Mode (see

below) must be used to display RPM or other rates.

1.1.2

Frequency Mode

In the Frequency Mode, the unit displays input pulses per second or more commonly,
Hertz (Hz). This is the most basic mode of operation. The range of measurement in this
mode is 0.0833 to 250,000 Hz.

1.1.3

Scale Mode (Ratemeter)

In the Scale Mode of operation, the input frequency (pulses per second) is multiplied by a
constant, which is set by the user and displayed. This allows the user to scale the input to
obtain a read out in any units required: RPM, inches per second, meters per hour, yards per
fortnight, and so on. The scale factor may be set anywhere from 0.0001 to 9999.9.

1.1.4

SECAP (Single Event Capture) Mode

The SECAP (Single Event Capture) Mode is just like the Scaling Mode except that only
one reading is made
. The RESET button is pressed to start each new measurement. The
unit will then use the next input pulse to start a measurement. Then the next input pulse will
end the measurement. In the other tachometer modes, the unit will keep acquiring pulses
until 32 mS (or 4mS) has passed so it can give an accurate reading. The SECAP Mode
sacrifices accuracy as measurements get shorter than 32 mS (or 4mS), but it is the only way
to measure single (non-repeating) events. Refer to Appendix C - Using the Single Event
Capture Mode
.

1.1.5

Rate of Change (ROC) Mode

In the Rate of Change Mode, the unit displays the rate of change of the input frequency
(pulses per second). The unit measures the input frequency times the scale factor set by the

22

APPENDIX B - SOME USEFUL CONVERSIONS:

Multiply By

To

Get

Inches 2.5400

Centimeters

Centimeters 0.3937

Inches

Inches 254.0000

Meters

Meters 39.3700

Inches

Feet 30.4800

Centimeters

Centimeters 0.2381

Feet

Feet 0.3048

Meters

Meters 3.2810

Feet

Yards 0.9144

Meters

Meters 1.0940

Yards

Miles 1.6090

Kilometers

Kilometers .6214

Miles

Miles 1609.0000

Meters

Meters 6.214

x

10

-4

Miles

Miles 160900.0000

Centimeters

Miles 5280.0000

Feet

Furlong 66.0000

Feet

Knots 6080.0000

Feet/Hour

Knots 1.1520

Miles/Hour