4. SUMMARY TAB

Once data has been loaded or read from the logger, the
following Data Summary screen opens. Note that only the
minimal amount of data needed is uploaded from the logger.

This is the Data Summary page. This page shows an overview
of the data and the state of the logger. It identifies the logger
type and Unit Tag, a name provided by the user, and the
serial number which is set at the factory. It shows the time
the recording started, the time of the last sample taken,
which may not be the end of the recording.
It also shows the number of samples in memory and the
Record Status. Record status can be On (still recording) or
Off. If the Record Status is Off and there is no Last Sample
value, it means the unit is waiting to start, either on delay or
button press. If the Record Status is Off and there is a Last
Sample value, the recording is complete.

There is also an overview of the Alarm Status. A

RED

box next

to the Alarm number (1,2,3 or 4) indicates that alarm
condition was exceeded. A GREEN box indicates that alarm
condition did not occur. If there is a box with an “X” in it, this
indicates the alarm is not active. (Alarm 3).

The alarm is indicated as High

or Low

with the

value to the far right. So in this example, Alarm 1 which was a
high alarm of 80°F was exceeded. Alarms 2 and 4 did not
occur and Alarm 3 was not active.

The User has the choice at this point to load all the data by selecting the Data Tab or the Graph Tab. In
either case the logger needs to be held in the NFC antenna area for the duration of the read which will
be around 8 to 10 seconds.

If no alarms occurred the user can choose to NOT load the data. The summary information can be
emailed to a remote location by pressing the SEND EMAIL icon shown above. This will attach a .bin file
which contains this summary information to the email. This file can be read on a PC using the available
PC software.

The logger can be reconfigured and set for a new recording by pressing the CONFIG LOGGER icon at the
bottom of the page. See

Section 7

.

SUMMARY TAB