In-line filter – Great Plains NTA2007HD Operator Manual User Manual

Page 121

Advertising
background image

Great Plains Manufacturing, Inc.

Contents

Index

Maintenance and Lubrication

117

04/04/2011

Contents

Index

166-283M

In-Line Filter

If folding/unfolding times slow noticeably, check the in-
line filter and clean if needed. The filter is located at the
inlet port of each pressure valve (page 155).

1.

Move drill to typical field conditions. Unfold drill
(page 30). Lower openers (page 36). Turn on fan
(page 58) and bring up to normal field rpm.

2.

Set Fan/Fold circuit to Float.

3.

Shut down tractor and remove key.

Refer to Figure 104
4.

Slowly loosen filter and relieve any residual pressure
in line. When disconnecting hose, support the end to
minimize fluid loss.

5.

To disassemble unscrew end cap of filter. Remove
top retaining washer and screen.

6.

Clean filter screen with solvent and compressed air,
or replace if needed.

7.

When reassembling put screen into filter. Place
retaining washer on top of filter and screw on end
cap.

8.

Re-install filter.

9.

Activate the Fan/Fold circuit. Cycle the lift and fold
systems several times. Check for leaks.

10. If there is any sign of air in the system, perform a

bleed operation (page 116).

Null4:

Figure 104

In-Line Filter

25187

Advertising
This manual is related to the following products: