Problem clean-outs, Removing meter box – Great Plains ADC2350BE Operator Manual User Manual

Page 81

Advertising
background image

Great Plains Manufacturing, Inc.

Table of Contents

Index

Maintenance and Lubrication

77

2012-08-01

Table of Contents

Index

167-085M

Problem Clean-Outs

For normal unloading of residual materials at completion
of planting, see “Unloading the Cart” on page 47. If,
however, parking and storage recommendations have
not been followed, it is possible to have hard-to-remove
material present.

If the material fails to pass through the clean-out door,
take the following steps to remove it. Do not consider
entering the hopper until first completing these tasks.

Open the clean-out door.

Remove the strainer and evaluate the problem.
For example:

• If the problem is a single moveable large object, such

as a dead animal, fishing out from above may be the
solution.

• If the problem is congealed materials, scoop out a

sample from above and see if the mass dissolves in
water. If so, and there is a small amount of the material
involved, rinsing, or rinsing and pumping the hopper
from above may be the solution.

For small amounts of residual materials, poking with a
long pole may suffice to push it through the clean-out.

If poking doesn’t produce satisfactory results, and you
intend to try wash-out, at least poke one hole down to the
clean-out, so that water can flow out.

If wash-out is contemplated, start by introducing a small
amount of water, and make sure that it appears at the
clean-out within 15 minutes. If not, you will just be adding
water to the problem. The hopper is not designed to hold
water at full capacity. Add no more, remove meter box
instead, and clean out from below.

Removing Meter Box

Removing the meter box exposes 7

×7 inch access holes

through which stubborn material may be extracted.

Refer to Figure 88
1.

Not shown: Loosen the gearbox-to-meter chain idler
and remove the chain. Disconnect inlet and outlet
hoses. Disconnect or remove the seed rate sensor.

2.

Loosen all the nuts

securing the meter box

to

the hopper bottom plate

. Unscrew the nuts to the

bolt ends, but do not completely remove the nuts.

3.

The meter box has a bead of silicone sealant
between it and the bottom plate. Use a pry tool to
free the meter box from the bottom plate.

4.

Once hanging entirely on the loose bolts, remove the
nuts and lower the meter box from the hopper.

When re-mounting the meter box, scrape off the old
silicone sealant and replace it with fresh sealant.

Figure 88

Remove Meter for Cleaning

26408

1

3

2

1

2

3

Advertising