Inductor (optional equipment) – Great Plains TS1000 Trailer Sprayer Operator Manual User Manual

Page 23

Advertising
background image

Great Plains Mfg., Inc.

Operating Instructions

7/6/09

21

TS1000 Trailer Sprayer 500-111M

4.

Operate the pump with the sprayer stationary, and
rinse the tank until 1/3 of the flush tank volume (33 gal-
lons) is consumed and then stop the pump.

5.

With the sprayer pump off, turn the agitation valve #1
from “FLUSH” to “OFF”.

Refer to Figure 14

6.

Rotate the flush tank valve #2 from “FLUSH TANK” to

“MAIN TANK”.

7.

Operate the pump and spray out the full volume of liq-
uid (deposited into the main sprayer tank from the
Flush Tank) in the field just finished.

8.

Repeat steps two through seven twice more until the
flush tank is empty and the main sprayer tank has
been rinsed completely three times.

9.

Reset the agitation pressure before filling the main
sprayer tank again.

Inductor (Optional Equipment)

The chemical inductor provides a safe and easy way to put
the chemical into the tank which keeps an operator from
having to climb up on the walkboard and dispense the
chemical into the tank from the tank lid. Placing the chem-
ical into the inductor tank allows it to transfer the chemical
into the sprayer tank. Follow the following instructions to
use the inductor tank.

Refer to Figure 15

1.

Fill the main sprayer tank with the carrier needed and
transport the sprayer to the field where the sprayer will
be used.

2.

Make sure the boom section valve switches are all off
and operate the pump.

3.

Turn the product valve #4 from “OFF” to “INDUCT”.

4.

Add chemical to inductor tank.

5.

Turn tank valve #2 to “MAIN TANK” and quick fill valve
#3 to “SPRAY”. Turn agitation #1 to “AGITATION”. Be
sure the valve to the tank is open.

6.

Turn inductor valve #5 from “INDUCTOR OFF” to “IN-
DUCTOR ON”.

7.

Add additional chemical as needed into the inductor
tank.

8.

When finished, turn inductor valve #5 from “INDUC-
TOR ON” to “INDUCTOR OFF”, rotate product valve #4
from “INDUCT” to “OFF”, and turn off pump in that or-
der.

Figure 15

Product Valve and Inductor Valve

14993

Figure 14

Control Panel

22673

Advertising