Troubleshooting

7/6/09

25

TS1000 Trailer Sprayer 500-111M

Troubleshooting

Problem

Problem Area

Specific Checks

Solutions

Pressure decreasing

Between gauge
and liquid sup-
ply

Pump wearing

Rebuild or replace pump

Plugged suction or pump to pressure
head hose

Clean hose and reduce cause of
clogging

Plugged Whirlfilter

Clean out Whirlfilter

Plugged gauge

Remove quick disconnect fitting
and flush gauge protector

Pressure fluctuating

Between pump
outlet and liquid

Check suction hose & fittings for air
leaks. Air in system is indicated by
buffs of air at nozzles

Remove obstruction from clogged
area

Vortex in tank suction

Align agitators properly

Cracked pump housing

Replace pump housing

Pressure increasing

Between gauge
and nozzle

Nozzle screens clogged

Clean screens

Nozzle orifices plugged

Remove material with soft brush or
air

Boom hoses becoming clogged

Remove obstruction from clogged
area

Boom hoses pinched

Use cable ties to position hose so
it will not kink

Pressure cannot
increase

Pump or elec-
tric ball valve

From nozzle charts check liquid
demand against pump capacity (noz-
zle requirement + agitation require-
ment)

Reduce swath width by nozzle
reduction; install smaller nozzles
and drive at a lower rate of speed

Electric ball valve or gauge not func-
tional

Replace or repair

Pressure adjust switch faulty

Test switch & replace if faulty

Fuse is out in control box

Replace fuse

Manual pressure adjustment valve not
all the way open

Open the manual pressure valve all
the way and allow the electric ball
valve to govern the pressure

No pressure

Plumbing

Tank shut-off valves off

Make sure all tank shut-off valves
are open

Loose fittings

Tighten fittings so pump can prime

Collapsed suction hose to pump

Replace hose

Obstruction in suction hose or tank

Remove obstruction

No pressure

Pump

Hydraulic pump running in the wrong
direction

Switch hydraulic hoses in tractor
outlet

PTO pump coupler loose

Tighten PTO coupler

Pressure cannot
decrease

Pump or elec-
tric ball valve

Tank agitation restricted

Check that agitator valve is open
and that liquid is being agitated

Liquid will not induct

Chemical Induc-
tor

Make sure the valve below the inductor tank is open

Make sure the pump is in operation and has prime

Make sure the venturi bypass valve is open

Inductor overflow

Chemical Induc-
tor

Close valve below inductor tank until pump is running, has pressure and venturi
valve is open