10 and 20 series meter slide maintenance, Replacing meter slide – Great Plains 3N-4025P Operator Manual User Manual

Page 144

Advertising
background image

140

3N-40P

Table of Contents

Index

Great Plains Manufacturing, Inc.

196-538M

Table of Contents

Index

2014-01-29

10 and 20 Series Meter Slide
Maintenance

For proper seeding operation, seasonally or when
changing crops, check meter slide for wear. If you have a
noticeable increase in seeding rate you may need to
replace the meter slide.

1.

Clean out seed meter. See “Cleaning Out 10 and
20 Series Meters
” on page 138.

2.

Remove wheel. See “10 and 20 Series Meter
Wheel Replacement
” on page 89.

Refer to Figure 189
The slide

is located at the front of the meter.

3.

Check for excess wear on meter slide

. Slight wear

at the top corner is normal.

4.

If slide is not excessively worn, stop here. If it is,
continue with step 5 to replace.

Replacing Meter Slide

Refer to Figure 190
5.

Remove retaining clip and pin

from meter.

Note: Meter slide

is spring loaded. Two meter slide

springs

will be released when you pull the pin,

and a third

when you tilt it back. Use care not to

lose pins and springs.

6.

Check removed pin

for wear and replace if worn.

7.

Place springs in new meter slide. Insert in meter and
pin in place.

8.

Re-install meter wheel (page 89).

9.

Close and pin meter clean-out (page 138).

Figure 189

Singulator Meter Slide

27467

1

1

1

Figure 190

Meter Slide Replacement

27468

3

4

5

2

2

3

4

5

2

Advertising