ADS Eureka Digital System User Manual

45

The velocity value is then displayed and shown as calculated. The
manufactured leak is then turned off, allowing for location of the unknown
leak with improved accuracy.

Note:

Measuring velocity using this method does not account for

more than one pipe material because it can only measure the
average velocity over the given pipe length.

Velocity Calculation (3-Transducer Mode)

This mode involves three transducers and the actual leak (i.e., no
intentional leak).

Enter the position of the center transducer as the distance from the left
transducer.

Select the appropriate tabs to display up to three correlation graphs.

Two correlations occur between sensors; the third occurs out-of-bracket.

Click on the Calculate button. The following dialog displays:

Advertising