Elster/kent helix & domestic meters – ADS Environmental Services PrimeWorks QR 775018 A0 User Manual

Page 82

Advertising
background image

ADS PrimeWorks User Manual

76

Elster/Kent Helix & Domestic Meters

Meter

PU10/LRP

PU100/HRP

(mm)

FCAL

Helix 2000

40-80

10

1

100-300

100

10

Helix 3000

40-80

10

1

100

10

1

150

100

10

Master 2000

40-50

1

0.1

80-100

10

1

PVG100

PV14/BPG20

Helix 4000

80-125

10/1000

1

150-300

100/10000

10

PSM

MSM

PSM-PS15-PS20
(V100)

15/20

0.5

PSM-PS25-PS30
(V100)

25-30

5

PSM-PS40 (V100)

40

5

PSM-LT (V210)

15 & 20

0.5

MSM-T (V100)

1

KVM-T (V200)

1

MSM-RS

10

Supplementary Notes:

FCAL = NUMBER OF LITERS PER PULSE

Kent Meters:

* Some earlier 100-mm meters require the following:

FCAL = 100(PU10/LRP) or 10(PU100/HRP). These meters can be distinguished by the center
pointer dial registration = 1000 liters/rev.

** Applies to 7-digit counters only. The other FCALs apply to the 8-digit counters.

Kent combination meters use a Helix 3000 meter as the main meter and a PSM-T as the secondary
meter. Select the appropriate FCAL from the table above for each of the meters.

The Master 2000 meter has been discontinued.