320d – Aphex 320D Compellor User Manual

Page 11

Advertising
background image

320D

Compellor

Page 10

Page 11

4.4 Power Cord
The Compellor uses a standard IEC power cord set. The appropriate mains plug for each

country is normally shipped with each unit. However, if you must install or replace the plug,

use the correct wiring code as follows:

4.5 Mounting In A Rack
The Compellor occupies one standard 19 in. x 1 3/4 in. rack space (1RU). Chassis depth is

9 1/2 inches not including connectors. Allow at least 3 inches additional space in back for

wiring and connectors. The chassis is designed to be fully supported by front panel mounting

alone. To avoid cosmetic damage to the panel, use the cushioned rack screws provided in

the shipping kit or other cushioned rack screws.

4.6 Proper Ventilation
A Compellor runs warm because the product was designed to efficiently conduct most of

the circuitry’s heat directly to the exterior surfaces. This keeps the hot internal components

such as voltage regulators running far cooler than if they relied on direct convection cooling.

Therefore, if the chassis seems unusually warm to the touch, you need not be alarmed since

the inside of the chassis is never much warmer than that. However, we do not recommend

installing a Compellor in a space which severely restricts air ventilation around the unit such

as a totally sealed rack enclosure unless you can provide an empty rack space above and

below the unit to facilitate cooling. Typical rack enclosures with louvers or fan cooling are

recommended in which case you can install the Compellor in any available rack space.

4.7 Panel Security
A transparent security cover is available through any Aphex dealer to fit your Compellor. This

is absolutely the most convenient way to protect your installation from tampering. When

ordering, ask for Aphex part number SC-1.

4.8 Tools And Equipment Needed
Only standard technician’s tools are required to install the Compellor. Additional test equip-

ment is required for servicing as will be indicated in the related sections of this manual.

4.9 Safety Considerations
Aphex has taken care to insure the safety of its products. The Compellor is constructed to

comply with international electrical safety standards.

To minimize the risk of shock or fire, do not expose the unit to moisture. Allow adequate

ventilation around the unit for cooling. Make sure the mains voltage is properly selected. Do

not open the chassis cover: there are no user serviceable parts inside.

USA Color Code

Black = Hot (live)

White = Neutral

Green = Ground

IEC/Continental Color Code

Brown = Hot (live)

Blue = Neutral

Yellow/Green = Ground

Power Cord Color Codes

Advertising