WaterTec S100 Manual June08

Note: It is critical that the soil is well saturated with water, otherwise the
moisture threshold calibration in Step 7 will fail. It is also important that you
complete Step 7 within one hour of saturating soil.

note

note

Note: If the biSensor receives water during this 24 hour period, or was not

saturated during Step 6, the calibration will either fail entirely or set an

incorrect threshold for your lawn. If this happens, you will need to

resaturate the soil and restart Step 7.

Step 6

Verify All Connections

Reconnect biSensor to desired valve. Verify that all connections are functioning properly after

the biSensor has been buried.

1. Verify communications with biSensor by pressing the “Read / Set” button. A numeric

reading indicates success. A display of Er1 or Er2 indicates a wiring error. Consult the

Troubleshooting section on pgs 11-12 If you receive an error.

2. If the numeric reading is below 20, the biSensor has excessive air pockets around it. If

this occurs, rebury the biSensor as per Step 5 taking extra care to ensure the soil is well

compacted around the biSensor.

3. Manually run the station connected to the biSensor. This will verify connection.

Step 7

24 Hour Moisture Threshold Calibration

The S100 comes with an auto-calibration capability that will set the moisture threshold

based on your soil type. This is useful for new installations. Before running the moisture

threshold calibration; ensure that the soil around the biSensor is heavily saturated with

water as instructed in Step 5. If not properly saturated, the calibration will fail. Write down

the current date, time and sensor reading to be used as a reference point.

Date ________________ Time ____________ Sensor Reading _________________

1. Hold the (+)(-) and (Bypass) buttons simultaneously for 3 seconds. The screen will flash

between “CAL” “24H” and the current moisture reading. The “24H” will count down on

the hour until the calibration is complete. Watering is paused during this time. It is

important that the biSensor does not receive any water during calibration. This process

will fail or provide false feedback if it does.

2. If the calibration succeeds, the moisture threshold will be automatically set, and the

system will allow watering when soil moisture drops below this threshold.

If an error occurs during calibration, the screen will flash “Er4” indicating calibration failed,

and then another “Er#”. This # represents the reason for failure. See Troubleshooting for

information on the various error messages. The S100 will need to be re-calibrated. In addition,

in the event of a failure, the S100 will go into “bypass” mode allowing for normal timer-based

watering

Note: If you need to exit this mode early, hold the (Read / Set) button for 3 seconds.

Note: All connections need to be submersible. DBY or equivalent on the valve

side is recommended. There are several products on the market that will

accomplish this. Follow the manufacturer’s instructions for the product you

choose.