When charging a large capacity battery or totally discharged battery, 

excessive current may force the DC breaker to turn off.

In such cases, use a battery charger to charge a large battery with AC 

output.

Battery defects may cause the DC breaker to trip. Check the battery 

before resetting the DC breaker.

DC Application

The DC terminal is used only for charging 12 volt batteries. It provides up 

to 12V - 8.3A (100W) of maximum power. 

Connection of Cable

Connect positive terminal (red) on generator to positive (+) terminal on 

battery.

Connect negative terminal (black) on generator to negative (-) terminal on 

battery.

Safety Precautions While Charging

WARNING

An explosive hydrogen gas is discharged through vent 

holes in the battery during the charging process. Do not 

allow spark or open flame around the generator or 

battery during the charging process.

Electrolyte fluid can burn eyes and clothing. Be careful to avoid 

contact. If injured, wash the affected area immediately with large 

quantities of water and consult a doctor for treatment.