BE Pressure supply 6800 Watt Generator BE6800HER User Manual

Page 26

Advertising
background image

26

Stopping The Generator

1. Turn off the power switch of the electric equipment and unplug the 

    cord from receptacle of the generator.

2. Allow the engine about 3 minutes to cool down at no load before 

    stopping.

3. Push the engine switch to the OFF position.

4. Push switch to the OFF position.

Oil Sensor

The oil sensor detects the fall in oil level in the crankcase and 

automatically stops the engine when the oil level falls below a

predetermined level.

When the engine has stopped automatically, turn off the generator, and 

check the oil level. Refill engine oil to the upper level as instructed  and 

restart the engine.

stopping

the

generator

CAUTION

DO NOT remove oil sensor probe when refilling with oil.

Remove oil filler cap on the opposite side of carburetor.

Advertising