TO CHECk SAFETY VALVE

Risk of Bursting.

If the safety valve

does not work properly, over-

pressurization may occur, causing

air tank rupture or an explosion.

Risk from Flying

Objects. Always

wear certified safety equipment:

ANSI Z87.1 eye protection (CAN/

CSA Z94.3) with side shields.
Before starting compressor, pull the

ring on the safety valve to make sure

that the safety valve operates freely. If

the valve is stuck or does not operate

smoothly, it must be replaced with the

same type of valve.

TO DRAIN TANk

Risk of Unsafe

OperationAir tanks

contain high pressure air. keep face

and other body parts away from

outlet of drain. Use ANSI Z87.1 eye

protection (CAN/ CSA Z94.3) when

draining as debris can be kicked up

into face.

Risk from noise.

Use ear protection

[ANSI S12.6 (S3.19) hearing

protection] as air flow noise is loud

when draining.
NOTE:
All compressed air systems

generate condensate that accumulates

in any drain point (e.g., tanks, filter, after-

coolers, dryers). This condensate con-

tains lubricating oil and/or substances

which may be regulated and must be

disposed of in accordance with local,

state, and federal laws and regulations.
1. Set the Auto/Off switch to "Off"

and unplug unit.

2. Pull the regulator knob out and

turn counterclockwise to set the

outlet pressure to zero.

3. Remove the air tool or accessory.
4. Pull ring on safety valve allowing

air to bleed from the tank until

tank pressure is approximately 20

psi. Release safety valve ring.

5. Drain water from air tank by open-

ing drain valve (counter-clockwise)

on bottom of tank.

Risk of bursting.

Water will condense

in the air tank. If not drained, water

will corrode and weaken the air tank

causing a risk of air tank rupture.

Risk of property

damage. Drain water

from air tank may contain oil and rust

which can cause stains.
6. After the water has been drained,

close the drain valve (clockwise).

The air compressor can now be

stored.

NOTE: If drain valve is plugged,

release all air pressure. The valve can

then be removed, cleaned, the rein-

stalled.

AIR FILTER

Hot surfaces. Risk

of burn. Outlet

tube, pump head, and surrounding

parts are very hot, do not touch.

Allow compressor to cool prior to

servicing.
1. Place Auto/Off switch to "Off".
2. Allow unit to cool.
3. Remove filter cover from base.
4. Remove element from filter base.
5. Place new element back in filter

base. Purchase replacement parts

from your local dealer or autho-

rized service center. Always use

identical replacement parts.

6. Snap filter cover to filter base.

Risk of property

damage. Do not

operate without air inlet filter

Advertising