TROUBLESHOOTING

Risk of Unsafe Operation. Unit cycles automatically when

power is on. When servicing, you may be exposed to

voltage sources, compressed air, or moving parts. Before servicing unit

unplug or disconnect electrical supply to the air compressor, bleed tank of

pressure, and allow the air compressor to cool.

PrOBLeM

CAUSE

CORRECTION

Excessive

tank pressure

- safety valve

pops off.

Pressure switch does not

shut off motor when

compressor reaches

"cut-out" pressure.

Move Auto/Off lever to the

"Off" position, if the outfit

does not shut off contact a

Trained Service Technician.

Pressure switch "cut-out"

too high.

Contact a Trained Service

Technician.

Air leaks at fit-

tings.

Tube fittings are not tight

enough.

Tighten fittings where air can

be heard escaping. Check

fittings with soapy water solu-

tion.

Do Not Overtighten.

Air leaks at or

inside check

valve.

Check valve seat damaged.

Replace check valve. Refer to

the

To Replace Check Valve

in the Service and Adjustment

section.

Air leaks in air

tank or at air

tank welds.

Defective air tank.

Air tank must be replaced. Do

not repair the leak.

Risk of

Bursting

Do not drill into, weld or

otherwise modify air tank or

it will weaken. The tank can

rupture or explode.

Air leaks

between head

and valve plate.

Leaking seal.

Contact a Trained Service

Technician.