Self diagnostic function – Sony Trinitron KV-2199XDK User Manual

Page 4

Advertising
background image

– 4 –

KV-2199XDK

RM-952

The units in this manual contain a self-diagnostic function. If an error occurs, the STANDBY/TIMER lamp will automatically
begin to flash.
The number of times the lamp flashes translates to a probable source of the problem. A definition of the STANDBY/TIMER
lamp flash indicators is listed in the instruction manual for the user’s knowledge and reference. If an error symptom cannot
be reproduced, the remote commander can be used to review the failure occurrence data stored in memory to reveal past
problems and how often these problems occur.

1.

DIAGNOSTIC TEST INDICATORS

When an errors occurs, the STANDBY/TIMER lamp will flash a set number of times to indicate the possible cause of the
problem. If there is more than one error, the lamp will identify the first of the problem areas.

Result for all of the following diagnostic items are displayed on screen. No error has occured if the screen displays a “0”.

Diagnostic

Item

Description

• Power does not

turn on

• +B overcurrent

(OCP) or
overvoltage
(OVP)

• Vertical deflection

stopped

• Horizontal

deflection
overdrive

• White balance

failure (no
PICTURE)

• Micro reset

No. of times

STANDBY/TIMER

lamp flashes

Does not light

2 times

5 times

Self-diagnostic

display/Diagnostic

result

002:000 or

002:001~255
003:001~255
004:001~255

at the same time

005:000 or

005:001~225

101:00 or

101:001~225

Probable

Cause

Location

• Power cord is not plugged

in.

• Fuse is burned out F4601

(F)

• H.OUT Q511 is shorted. (A

board)

• IC701 is shorted. (C3 board)
• -13V is not supplied. (A

board)

• IC 503 faulty (A board)

• G2 is improperly adjusted.

(Note 2)

• CRT problem.
• Video OUT IC701 is faulty.

(C3 board)

• IC301 is faulty. (A board)
• No connection A board to

C3 board.

• Discharge CRT (C3 Board)
• Static discharge
• External noise

Detected

Symptoms

• Power does not come on.
• No power is supplied to the

TV.

• AC power supply is faulty.

• Power does not come on.
• Load on power line is

shorted.

• Has entered standby state

after horizontal raster.

• Vertical deflection pulse is

stopped.

• Power line is shorted or

power supply is stopped.

• No raster is generated.
• CRT cathode current

detection reference pulse
output is small.

• Power is shut down shortly,

after this return back to
normal.

• Detect Micro latch up.

Note 1: If a + B overcurrent is detected, stoppage of the vertical deflection is detected simultaneously.

The symptom that is diagnosed first by the microcontroller is displayed on the screen.

Note 2: Refer to screen (G2) Adjustment in section 3-4 of this manual.

SELF DIAGNOSTIC FUNCTION

Advertising