Sony Trinitron KV-2199XDK User Manual

Page 7

Advertising
background image

– 7 –

KV-2199XDK

RM-952

6.

SELF-DIAGNOSTIC CIRCUIT

[+B overcurrent ªOCPº]

Occurs when an overcurrent on the +B(135) line is detected by Q604. If Q604 go to ON
and the voltage to pin 18 of IC301 should go down when V.SYNC is more than seven
verticals in a period, the unit will automatically turn off.

[Vertical deflection stopped]

Occurs when an absence of the vertical deflection pulse is detected by Q509 and IC001
shut down the power supply.

[Vertical deflection overcurrent]

Occurs when an overcurrent on V drive line is detected by Q507. Power supply will be
shut down when detect this by IC001.

[White balance failure]

If the RGB levels* do not balance or become low level within 5 seconds, this error will be
detected by IC301. TV will stay on, but there will be no picture.

* (Refers to the RGB levels of the AKB detection Ref pulse that detects IK.)

IC301

Y/CHROMA JUNGLE

FROM

CRT

FROM

[+B]

Q604 C

[V]

Q509/507

IC001

SYSTEM

IC003

MEMORY

B-DAT

IO-SDAT

IK-IN

MP/
PROTECT

IO-8DAT

O-LED

SDA

5

45

21

18

51

46

35

Advertising