aintenance and care

Cleaning the secondary cyclone

Unplug the cleaner from electrical outlet.

1. The secondary cyclone can be reached by

removing the dirt container, reaching underneath

the upper tank and turning the rim of the frame to

unlock. Pull straight down to remove.

2. The cyclone and screen may be separated

for cleaning. Simply pull up on the screen to

separate.

3. The upper tank may also be wiped clean

with a damp cloth.

1. Unplug the vacuum from electrical outlet.

2. The Pre-Motor Filter protects the motor from

dirt particles. It is located in the slide out tray

underneath the Dirt Container. If the filter

becomes dirty, pull out the tray, lift out the fil-

ter and clean. This filter may be hand washed

in cold water with mild detergent. Rinse well

and air dry thoroughly before replacing.

3.

The HEPA Media Post-Motor Filter assists in the

filtration process to return clean air to the

room. It is located behind the door on the back

of the cleaner. If the filter becomes dirty, open

the door, remove the filter and replace. The

HEPA Media Filter is not washable.

Cleaning the pre-motor and post-motor filter

Pre-Motor Filter

WARnInG:

Do not operate cleaner

with damp or wet

filters or without all

filters in place.