background image

WARnInG:

To reduce the risk of electric

shock, turn Power Switch

Off and disconnect plug

from electrical outlet before

performing maintenance or

troubleshooting checks.

M

aintenance and care

Replace light bulb

1. Unplug cleaner from electrical outlet.
2. Remove detachable canister and recline

handle of vacuum.

3. Using a screwdriver, remove the one screw

as shown and lift off the lens.

4. Remove the bulb from the socket by grasping

bulb and pulling straight out. Install the new

bulb by pushing it gently into the socket until

the bulb snaps into place.

5. Reposition lens and secure with the one

screw.

TurboBrush maintenance

(TurboBrush™ Pet on select models only)
The TurboBrush should be checked

regularly for clogs or debris wrapping

around the brush roll.

1.

Unplug vacuum from electrical outlet.

2.

If a clog is present or debris is visible, unscrew

the two screws on the back of the TurboBrush to

remove the faceplate and clear any obstructions.

3.

To clean debris from the brush roll, remove the

screw located on the belt cover. lift the belt

cover. Remove the brush roll from the drive belt

and clean debris.

4.

Reposition the drive belt on the brush roll. Place

ends of brush roll in slots on sides as shown.

Reposition belt cover and secure with shorter

screw. Reposition faceplate and secure with two

longer screws.