CHAPTER 6

TROUBLESHOOTING

Most problems are easy to fix. Consult the Troubleshooting Table below for common problems and their
solutions. If you continue to experience problems, call Country Home Products, Inc. for support.

Troubleshooting Table






S

YMPTOM

P

OSSIBLE

C

AUSE

No output voltage at
any outlet.

⇒ The PTO (Blade Drive) is not engaged.
⇒ The Generator Drive Belt is broken or fell off the pulleys. Replace the

Drive Belt and be sure the Belt Tension Lever is secured. See page 12.

No output voltage at
one or more outlet.

⇒ The circuit breaker has tripped for the outlet in question. Reset the

breaker by pushing the breaker button in until it clicks in the closed
position. See page 17.

A circuit breaker trips
when an appliance or
tool is plugged in.

⇒ Defective (shorted or wet) power cord on the appliance or tool, or in

the extension cord, if one is being used. Replace the power cord per
the appliance or tool instruction manual or replace the extension cord.

⇒ If the problem persists, call:

1(800) DR-OWNER (376-9637) for assistance.

A circuit breaker trips
when an appliance or
tool is turned on.

⇒ Check that the rated power and surge power required by the appliance

or tool is within the Generator output specification. See page 21.

⇒ If the problem persists, call:

1(800) DR-OWNER (376-9637) for assistance.

ATM stalls when PTO
is engaged to start the
Generator.

⇒ Be sure the Generator power switch is OFF.
⇒ Be sure the Generator Wire Harness is plugged into the Relay Wire

Harness. See page 14, Figure 17.

⇒ Hold down the Operator Presence Lever while engaging the PTO.

When the Generator is up to speed, release the Operator Presence
Lever.

WHEN PERFORMING ANY MAINTENANCE ON THE DR GENERATOR ATTACHMENT WHEN
THE UNIT IS STILL ATTACHED TO THE ATM, YOU MUST FIRST DISCONNECT THE SPARK
PLUG WIRE(S) ON THE ATM.

ONLY A LICENSED ELECTRICIAN SHOULD REMOVE THE COVER OR FRONT PANEL OF THE
GENERATOR.