3 menus – Baumer BA Scatec10 15 User Manual

Page 26

Advertising
background image



User manual Scatec-10 / -15

26 / 44

Baumer Electric AG

Version 2011-03

www.baumer.com

Frauenfeld, Switzerland

10.3 Menus

10.3.1 Menu A:

Summary

[Summary]


Menu A presents a summary of the current parameter setting.

In menu A, no parameters can be set. It serves only as a display.

Submenus that are not applicable in the current setting are not shown. For example: submenu A3 does not
show up if a factory preset level was chosen for sensitivity.

If you have to contact a technician from Baumer Electric because of a problem with the Scatec, always have
the parameter values on hand shown in this summary menu.

Submenu

Values

Comments


A1:


abcd efg
hhhhh iiiii

a False pulse suppression mode

0 = dynamic dead time

1 = synchronous dead time

2 = fixed dead time

3 = retro-reflective foil only

* = not activated

b Pulse delay

0 = immediate pulse delivery

1 = delayed pulse delivery

* = not activated

c running direction

0 = leading

1 = trailing

* = not activated

d Output pulse triggered by last edge

0 = first edge triggers output pulse

1 = last edge triggers output pulse

* = not activated

e Short pulse suppression

0 = no short pulse suppression

1 = short pulses will be suppressed

* = not activated

f A/B Encoder

0 = only A-channel of the encoder is used

1 = A- and B-channel of the encoder are used

* = not activated

g Sensitivity level

1 = highest

2 = medium

3 = low

4 = very low

* = customized

h Dead time or path

xxxyy length of dead time or path with unit

i Output pulse delay

xxxyy delay of the output pulse with unit


A2:

Length Resol


aa.a b.bb

Output pulse length and encoder resolution

aa.a

output pulse length in milliseconds

b.bb

encoder resolution in millimeters /
pulse


A3:

Thresh/Hyst.


aaa bbb

Threshold and hysteresis

aaa

customized threshold

bbb

customized hysteresis

Advertising