C10:

Pulse Delay

xxx ms

Output pulse delay in ms

value of output pulse delay in milliseconds

C11:

Pulse Delay

xxx mm

Output pulse delay in mm

value of output pulse delay in millimeters

C12:

Out@PlsTrain

0 = first

1 = last

Output pulse triggered by last edge

output pulse triggered by first edge of edge train

output pulse triggered by last edge of edge train

C13:

Tail.Suppr.

0 = stand

1 = extnd

Tail edge suppression

edge suppressed if it is followed by a retro-

reflective foil within the dead time

edge suppressed if it is followed by a retro-

reflective foil within the output pulse delay
time

C14:

ShrtP.Suppr.

0 = off

1 = on

Short pulse suppression

short edges will not be suppressed

short edges will be suppressed

C15:

Sensvty Mode

0 = stand

1 = custm

Sensitivity mode

standard sensitivity levels as defined in C16 will be

activated

sensitivity as defined by customer in C17 and in C18

will be activated

C16:

Sensvt Level

01 = high

02 = mid

03 = low

04 = v.low

Sensitivity level

highest

medium

low

very low

C17:

Threshold

xxx

Threshold

C18:

Hysteresis

xxx

Hysteresis

value of the hysteresis