2 Description

2.1 System description
The process display is intended as indicator for measured values in

industrial applications.

-Voltage input ±10 V, ±20 VDC, ±200 VDC

-Voltage input ±100 mVDC for current measurement by external

resistor Shunt (measuring resistor)

-Current input ±20 mA

-Optionally linearized display

-LED display, 4 digits, programmable

-DIN housing 48 x 24 mm

2.2 Display range

Linear increase: Display scaling defines interaction of input signal and displayed

value. Linear behavior requires defining two measured values

- (inP) respectively displayed values (dSP). Both limits should be at

the end of the display area to ensure maximum precision.

Displayed

value 2

Displayed

value 1

Measured

value 1

Measured

value 2

Linear decrease: There are two options to enter the value coordinates: Either by

keypad (in SCAL mode) or using the teach-in feature (teach mode).

Assigning the displayed values requires manual entry (with device

still in teach mode). Scaling is enabled at standard signal ±10 V, ±20

mA and shunt.