Denex, 3 electrical installation – Baumer BA DenexEdgeDetectorII User Manual

Page 6

Advertising
background image

User Manual DENEX Edge Detector II

6/20

Baumer Electric AG

Version 2013-02, V1.6

www.baumer.com

Frauenfeld, Switzerland


DENEX

Laser CopySensor™
Edge Detector II

DENEX Systems Technology AB Solkraftsvägen 3 1, S-135 70 Stockholm, Sweden
Tel : + 46 (8) 7 12 00 20 Fax: + 46 (8) 712 59 4 5 E- mail: [email protected]

DENEX

SYSTEM S
TEC HN O LO G Y

DEN EX

keeps an eye on your

pr oducti on

R

Figure 3.2.2 Mechanical mounting with reference surface.

3.3 Electrical installation

The interface to the copy sensor is a 7-pin connector with the following pin-out:
Matching connector: Amphenol Tuchel T3476 001, delivered with the sensor.

Pin 1 :

+24VDC in

Pin 2 :

+ Output (collector)

Pin 3 :

Not connected

Pin 4 :

Not connected

Pin 5 :

- Output (emitter)

Pin 6 :

0V

Pin 7 :

No function

3.3.1 Power Connection
Proper wiring techniques are essential for successful system installation. To reduce the
effects of electrical noise interference and static discharge, the procedures outlined in this
section must be strictly followed.
The sensor shall be connected to 24 VDC regulated power.
It must be free from transients!
Never connect or disconnect any cables when the power is on!
The normal current consumption is 150 mA.

3.3.2 Output Signal
The output is a normally open, opto-isolated transistor. Every output pulse is signaled as a
closing of the output for a certain time; see also “DIP-Switch Settings”
The specification for the output opto-coupler is as follows:
Max load current:

100 mA

Max voltage:

35VDC