N 140 – Baumer N 140 User Manual

Page 10

Advertising
background image

N 140

www.baumer.com

10

Example 2: Align actual value with preset (preset = 17,25)

SOH Adr Cmd

Preset = 17,25

EOT CRC

Transmission

01h 20h 5Ah 30h 30h 31h 37h 32h 35h

04h

09h

SOH Adr Cmd

Preset = 17,25

EOT CRC

Response

01h 20h 5Ah 30h 30h 31h 37h 32h 35h

04h

09h


Example 3: Align actual value with preset at all SPAs by broadcast command

SOH Adr Cmd

Preset = 17,25

EOT CRC

Transmission

01h 83h 5Ah 30h 30h 31h 37h 32h 35h

04h AAh

Response

Not confirmed


4.2.7. Readout any optional number sequence in the upper line of display,
command „t“ (74h)

This command is to indicate a 6-digit number sequence in the upper line of the display. The sequence is
indicated without dot respectively comma. Preceding zeroes as well as both direction arrows are suppressed.
The bottom line still indicates the current value.
The number is shown on the display until any command except „t“, „u“ or „R“ is received by interface. The
number will be retained after power failure.

Example: (number sequence = 654321)

SOH

Adr

Cmd

Number sequence = 654321

EOT

CRC

Transmission

01h

20h

74h

36h

35h

34h

33h

32h

31h

04h

47h

SOH

Adr

Cmd

Number sequence = 654321

EOT

CRC

Response

01h

20h

74h

36h

35h

34h

33h

32h

31h

04h

47h


4.2.8. Readout any optional number sequence in the bottom line of display,
command „u“ (75h)

The command is for indicating a 6-digit number in the bottom line of the display. The number is indicated
without dot respectively comma. Preceding zeroes as well as both direction arrows are suppressed. The upper
line still indicates the current target or tool number.
The number sequence is displayed until any optional command except „t“, „u“ or „R“ is received by the interface.
The number will be retained after power failure.

Example: (number sequence = 123456)

SOH

Adr

Cmd

Number sequence = 123456

EOT

CRC

Transmission

01h

20h

75h

31h

32h

33h

34h

35h

36h

04h

BCh

SOH

Adr

Cmd

Tool number = 123456

EOT

CRC

Response

01h

20h

75h

31h

32h

33h

34h

35h

36h

04h

BCh



Important:
Command “t” in conjunction with command “u” enables displaying a 12-digit number.
Tool number and number sequence are not saved.

Advertising