Parameter commands, Read / write bit parameter, command „a“ (61h) – Baumer N 140 User Manual

Page 11

Advertising
background image

N 140

www.baumer.com

11

4.3. Parameter commands

Command

code

Data amount

in bytes

read

write

Broad-

cast

Save in

EEPROM

Significance

a (61h)

5

X

X

-

X

Read / write general parameters

b (62h)

8

X

X

-

X

Parameter: Tolerance compensation, window

c (63h)

8

X

X

-

X

Parameter: Scaling spindle pitch

i (69h)

1

X

X

X

X

Parameter: mm / inch

x (78h)

5

X

X

-

X

Read / write specific parameters


4.3.1. Read / write bit parameter, command „a“ (61h)

To exploit maximum memory capacity, several parameters are put together and transferred as “data pack”
under the following parameter codes:

Data1: 1 0 X X 0 X 0 X

┬ ──┬── ─┬─ ─┬─

│ │ │ └─── positioning direction 0/1 (UP/DOWN)

│ │ └─────── counting direction 0/1 (UP/DOWN)

│ └──────────── arrows 0/1/2/3 (UP/DOWN/UNI/OFF)

└──────────────── 1

Data2: 1 0 X X X X 0 X

┬ ┬ ─┬─ ┬ ┬ ─┬─

│ │ │ │ │ └─── round current value 0/1 (OFF/ON)

│ │ │ │ └────── turn display 0/1 (OFF/ON)

│ │ │ └──────── dimension 0/1 (OFF/ON)

│ │ └─────────── offset 0/1 (OFF/ON)

│ └────────────── reserved

└──────────────── 1

Data3: 1 0 0 0 0 0 X X

┬ ────┬──── ─┬─

│ │ └─── hide target 0/1/2 (ON/OFF/EVER)

│ └────────── reserved

└──────────────── 1

Data4/5: 0 0 1 1 X X X X

───┬───

└───── reserved


Note: Only the bits marked ‘X’ may be altered. The permanent parameters „1“ and „0“ must not be altered since
this might create a control token ( tokens < 20h) what is not permitted in ASCII protocol.

Example 1: Read bit parameter (Data1 to Data3 = 80h; Data4 to Data5 = 30h)

SOH

Adr

Cmd

EOT

CRC

Transmission

01h

20h

61h

04h

4E

Bit parameter default


Example 2: Write bit parameter (positioning direction = down; turn display = On)

SOH

Adr

Cmd Data1 Data2 Data3 Data4 Data5

EOT

CRC

Transmission

01h

20h

61h

81h

84h

80h

30h

30h

04h

91h

SOH

Adr

Cmd Data1 Data2 Data3 Data4 Data5

EOT

CRC

Response

01h

20h

61h

81h

84h

80h

30h

30h

04h

91h

SOH

Adr

Cmd Data1 Data2 Data3 Data4 Data5

EOT

CRC

Response

01h

20h

61h

80h

80h

80h

30h

30h

04h

F1