Description of diagnosis data Slave_Diag (contd.)

Device

class

Diagnosis data

Octet no. Significance

2

Warnings

20, 21

Indicates when parameters are not within the admissible
tolerance. In contrast to alarm signals, these events do not
result in incorrect position values.

Voltage of the lithium cell has dropped below the critical
value (only multiturn encoders)

2

Supported warning
signals

22, 23

Indicates which warning signal is supported

Voltage of the lithium cell has dropped below the prescribed

value (only multiturn encoders)

2

Profile version

24, 25

Profile version of the encoder profile in revision number and
index

2

Software version

26, 27

Indicates the software version in revision number and index,
identical to the indication on the rating plate of the encoder.

2

Operating hours counter 28 to 31 Not supported

2

Offset value

32 to 35

Indicates the offset value stored in the EEPROM after a
preset

2

Manufacturer offset

36 to 39 Not supported, reserved for servicing purposes

2

Steps per revolution

40 to 43 Indicates the programmed steps per revolution of the encoder

2

Total resolution in steps

44 to 47

Indicates the programmed total resolution in steps of the
encoder

2

Serial number

48 to 57 Not supported

2

Reserved

58, 59

Not supported, reserved for servicing purposes