10.2.4. Terminal assignment


Pin

Terminal

Explanation

Pin 1

UB

Supply voltage 10...30 VDC

Pin 3

GND

Ground connection relating to UB

Pin 2

A

Negative serial data line

Pin 4

B

Positive serial data line


M12-connector
For serial data line


for supply voltage

male

female


Terminals with the same significance are internally connected and identical in their functions. Max. load on
the internal terminal connections UB-UB and GND-GND is 1 A.
A and B are each isolated for 12 MBaud operation with an inductivity of 100 nH

Carefully plug the bus cover onto the D-SUB plug of the basic encoder, then press only via the sealing
rubber, taking care not to tilt it. The bus cover must rest fully against the basic encoder.

Tighten both the fastening screws firmly in the same direction.


The encoder housing and braided shield of the connecting cable are only ideally connected if the bus cover is
resting fully on the basic encoder (positive locking).

10.3. Display element (status display)

A dual LED is integrated at the back of the bus cover.

Colour

Status

Green alight

Encoder in "Data_Exchange" mode

Yellow alight

Encoder ramping up

Red alight for 2.5 s

Wrong position value, caused by code constancy error

Red flashing, 1 Hz

Parameterization error

Red flashing, 5 Hz

Transmitted preset value in inadmissible value range