Ne215, Open interface description – Baumer NE215 User Manual

Page 32

Advertising
background image

32

NE215

7.10 Programming plan

Lines in

italic* = Factory setting

Line 11-18

Status for line 11-18
0 * Parameter can be changed
1

Clearing and/or input disabled

2

Parameter is skipped

Line 21

Operating mode principal count system
0 * Progressive preselections
1

P1 Trailing preselection

Line 22

Not applicable

Line 23

Scaling factor batch counter
00

Minimum value

1 * Default value
99

Maximum

Line 24

Not applicable

Line 25

Not applicable

Line 26

Frequency batch counter counting
0 * 10 kHz
1

25 Hz

2

15 Hz

Line 27

Not applicable

Line 28

Not applicable

Line 29

Not applicable

Line 30

Reset batch counter
0 * Autom. reset and external static
1

Autom. reset and external differential

2

External static

3

External differential

Line 31

Output time P1, (P2), (P3), B1
00.00 Maintained contact (LAtcH displayed)
0.25 * Default value
99.99 Maximal value

Line 32

Output time P1, (P2), (P3), B1
00.00 Maintained contact (LAtcH displayed)
0.25 * Default value
99.99 Maximal value

Line 33

Output time P1, (P2), (P3), B1
00.00 Maintained contact (LAtcH displayed)
0.25 * Default value
99.99 Maximal value

Line 34

Take-over of preselection P1, P2, B1
0 * In case of reset
1

After input

Line 35

Address for function key
0 * Function key not connected
:
8

Maximum value

Open interface description