User Manual DENEX Gripper LED

12/24

Baumer Electric AG

Version 2013-02, V1.4

www.baumer.com

Frauenfeld, Switzerland

To adjust the sensor to get a blocking of approximately 50 % do the following:

Make a bracket that enables the sensor to be moved sideways, or order one from

Baumer. Specify type of conveyor!

Set the sensor in Gripper Pulse Mode, see chapter 6.4

Watch the Output LED during production. It should be flashing.

The next step can be dangerous! Watch your hands if you do the movement during
run!

Move the sensor sideways until the Output LED is ON for approximately as long as it is

OFF to get 50 % duty cycle.

You can also check with a scope, either on the Output directly or between TP8 and

TP1, see chapter 6.

If this is done OK, the sensor will only count one edge for half a Gripper, which will be the
ideal situation.