ELECTRICAL INSTALLATION

The copy sensor has a 7-pin male connector with the following pin-out:

Matching female connector is Amphenol Tuchel T3476 001, delivered with the sensor.

Pin 1 :

+24Vin

Pin 2 :

+ Output (Collector)

Pin 3 :

+ Speed Sensor Input

Pin 4 :

- Speed Sensor Input

Pin 5 :

- Output (Emitter)

Pin 6 :

0V

Pin 7 :

No function (connected to pin 6 internally)

5.1 Power Connection

Proper wiring techniques are essential for successful system installation. To reduce the
effects of electrical noise interference and static discharge, the procedures outlined in this
section must be strictly followed.
The sensor shall be connected to 19 - 30V DC regulated power.
It must be free from transients!
Never connect or disconnect any cables when the power is on!
The normal current consumption is around 200mA.

5.2 Output Signal

The output is a normally open, opto-isolated transistor. Every output pulse is signaled as a
closing of the output; see “DIP-Switch Settings” in chapter 6.4.
The specification for the output opto-coupler is as follows:

Max load current:

150mA

Max voltage:

35V DC