4 dip-switch settings – Baumer BA DenexGripperLED User Manual

Page 13

Advertising
background image

User Manual DENEX Gripper LED

13/24

Baumer Electric AG

Version 2013-02, V1.4

www.baumer.com

Frauenfeld, Switzerland

6.4 DIP-Switch Settings

An 8-pole DIP-switch can be reached via the lid on top of the sensor. Unscrewing the
screw opens the lid.
The software can be controlled via the DIP switches.

DIP-Switch positions

= OFF

= ON


DIP-switches 1-4 are reserved for factory.
DIP-switches 5-8 are for selecting operation mode

All in OFF-position is the default setting.


DIP-Switches

5 6 7 8

Mode 0 =
Default

Standard newspaper: 15% Blocking, Output 5ms

Mode 1

Double production: 30% Blocking time. Output 5 ms

Mode 2

Gripper Pulse Mode Output NO, Reset on falling edge of speed sensor

Mode 3

Gripper Pulse Mode Output NC, Reset on falling edge of speed sensor

Mode 4

Gripper Pulse Mode Output NO, Reset on rising edge of speed sensor

Mode 5

Gripper Pulse Mode Output NC, Reset on rising edge of speed sensor

Mode 6

Gripper Pulse Mode Output NO, Reset on falling edge of speed sensor

Mode 7

Standard newspaper: 15% Blocking, Output 20ms

Mode 8

Double production: 30% Blocking time, Output 20 ms

Mode 9

Standard newspaper: 30% Blocking, Output 20ms

Mode 10

reserved

Mode 11

reserved

Mode

STATUS LED shows:

0

Lit when target is recognized by sensor

1

Lit when target is recognized by sensor

2

Speed sensor status

3

Speed sensor status

4

Speed sensor status

5

Speed sensor status

6

Lit when target is recognized by sensor

7

Lit when target is recognized by sensor

8

Lit when target is recognized by sensor

9

Not applicable