Explanation of parameter „a – Baumer N 141 User Manual

Page 12

Advertising
background image

N 141

www.baumer.com

12

Note: Only the bits marked ‘X’ may be altered. The permanent parameters „1“ and „0“ must not be altered since
this might create a control token ( tokens < 20h) what is not permitted in ASCII protocol.

Example 1: Read bit parameter (Data1 to Data3 = 80h; Data4 to Data5 = 30h)

SOH

Adr

Cmd

EOT

CRC

Transmission

01h

20h

61h

04h

4E



Example 2: Write bit parameter (positioning direction = Down; turn display = On)

SOH

Adr

Cmd Data1 Data2 Data3 Data4 Data5

EOT

CRC

Transmission

01h

20h

61h

81h

84h

80h

30h

30h

04h

91h

SOH

Adr

Cmd Data1 Data2 Data3 Data4 Data5

EOT

CRC

Response

01h

20h

61h

81h

84h

80h

30h

30h

04h

91h


Explanation of parameter „a“


Positioning direction
This parameter defines the positioning direction to head for the target. Compensating tolerances, for example at
cogwheels, joints, shafts etc during a precise positioning operation requires a tolerance compensation. The
tolerance compensation is proceeded by heading for the target position always from the same direction by so-
called loops. Loops mean that the target position is first crossed by a defined distance and then headed for from
the opposite direction. The parameter for the crossing distance is programmed by command “b”. Whether a loop
is required or not can be seen from the direction arrows on the display. A flashing arrow means tolerance
compensation required. Upon reaching the turning point the direction changes and the arrow stops flashing. A
target enabling direct positioning is marked by a non-flashing arrow. Upon reaching the target within the
programmed tolerances (see command “b”) the arrows will not disappear until the required tolerance
compensation was completed.

00 = Up

Direct positioning if target position > current position; otherwise proceed tolerance compensation

01 = Down

Direct positioning if target position < current position; otherwise proceed tolerance compensation


Counting mode
This parameter assigns either „ascending“ or „descending” counted values in relation to the shaft’s direction of
rotation. Following parameters are available:

00 = Up

Clockwise rotation, ascending counted values

01 = Down

Clockwise rotation, descending counted values


Arrows
This parameter relates to the arrows in the display that indicate the operator the correct direction (to the right or to
the left) of the new positioning operation. The following parameters are available:

00 = Up

If current value < target = arrow to the right; current value > target = arrow to the left

01 = Down

As „Up“, but inverted direction of the arrows

10 = Uni

If current value ≠ target indicate both arrows

11 = Off

Ever hide arrows

Rounding the current value
This means that the current value being within the tolerances but still differing from the target is rounded up or
down to the target value as soon as the shaft remains idle for approx. 3 seconds. The rounding operation is only
visual, the true internal current value remains unchanged. For current value readout by serial interface (command
“R”) the true, not rounded current position value is provided. The true current value will immediately reappear on
the display upon actuating a key. If the position is still within the tolerance window the rounding operation will be
repeated after 3 seconds.
Note: In operating mode „Hide target = Ever“ the target is deactivated and the SPA serves as a pure current
value display with disabled rounding function. The following parameters are available:

0 = Off

Rounding the current value disabled

1 = On

Rounding the current value enabled

SOH

Adr

Cmd Data1 Data2 Data3 Data4 Data5

EOT

CRC Bit parameter default

Response

01h

20h

61h

80h

80h

80h

30h

30h

04h

F1