Specific commands, Extended identifier command „ax“ (41h,58h), Spa profile reset, command „k“ (4bh) – Baumer N 141 User Manual

Page 16

Advertising
background image

N 141

www.baumer.com

16

Indicate identifier in the display, command „A“ (41h)

This command less parameters as a broadcast command (address/identifier=99) will make every networked
SPA indicate the device-specific identifier in the bottom line of the display. The upper line is blind.
This command is a desginated broadcast command.

SOH Adr Cmd EOT CRC

Transmission

01h 83h 41h 04h 80h

Response

Not confirmed



The SPA remains in this mode until being switched off and on again or until transmission of another command.

Extended identifier command „AX“ (41h,58h)

This extended command is utilized for addressing individual multicon devices in the bus network in a similar
way as described above. By broadcast command the identifier to be assigned is transmitted to all networked
devices as follows:

SOH

Adr

Cmd

Sub

identifier = 01

EOT

CRC

Transmission

01h

83h

41h

58h

30h

31h

04h

40h

Response

Not confirmed

Similar to standard command all devices now show the identifier just transmitted and that is to be assigned in
the upper line. Entering the identifier is proceeded the same way. However contrary to the above no
confirmatory command „B“ will be replied. It is up to master to check whether the identifier has been accepted,
for example by command “R” (read current value). The R-command is transmitted under the corresponding
identifier to the position display. If the addressed SPA is responding the assignment was successful and the
master can proceed with the next identifier. Regarding other commands the display of the respective device
switches to standard operation.

4.5. Specific commands

Command

code

Data

amount in

bytes

read

write

Broad-

cast

Save in

EEPROM

Significance

K (4Bh)

-

-

X

X

X

Specific command: Profile reset (delete)

Q (51h)

1

-

X

X

X

Specific command: N 141 reset

X (58h)

2 / 4 / 8

X

-

-

-

Specific commands


4.5.1. SPA profile reset, command „K“ (4Bh)

This command is deleting all previously programmed profiles.

Example 1: Profile reset at specific N 141

SOH

Adr

Cmd

Data

EOT

CRC

Transmission

01h

20h

4Bh

7Fh

04h

C6h

SOH

Adr

Data

EOT

CRC

Response

01h

20h

6Fh

04h

52h Device replies by standard response ‚o’ (6Fh) = OK


Example 2: Profile reset at all N 141 by broadcast command (Identifier=99)

SOH

Adr

Cmd

Data

EOT

CRC

Transmission

01h

83h

4Bh

7Fh

04h

DBh

Response

Not confirmed

Important: After profile reset all profile data are set to auf FFFFFFhex , the current profile number to FFhex.
The display now shows 6 dashes instead of the target.