N 141, Response upon deletion of all targets – Baumer N 141 User Manual

Page 8

Advertising
background image

N 141

www.baumer.com

8

4.2.3. Read current value and key status, command „T“ (54h)

This command is for readout the 6-digit current value (bottom line of the display) as well as the key status.
Amount of data is always 7 byte. Negative values will come with a “-“ sign (2Dh) together with 5 data bytes.
Positive values are transmitted by 6 data bytes less any sign. Values inferior to 6 (5) digits come with preceding
zeroes. The 7

th

data byte is comprising the key status. A readout operation is deleting the status of the actuated

key (21hex) so that any further readout will always be 20hex. Status 1 (21hex) will not be restored until the key
is actuated again.

Example: Current value = -32,50

SOH

Adr

Cmd

EOT

CRC

Transmission

01h

20h

54h

04h

40h

SOH

Adr

Cmd

Current value = –32,50

key

EOT

CRC

Response

key = 0

01h

20h

54h

2Dh

30h

33h

32h

35h

30h

20h

04h

E2h

SOH

Adr

Cmd

Current value = –32,50

key

EOT

CRC

Response

key = 1

01h

20h

54h

2Dh

30h

33h

32h

35h

30h

21h

04h

E0h


4.2.4. Read / write parameter target (profile), command „S“ (53h)

This command is for the presently active target readout or for programming respectively reading a specific
target. The data are composed of profile number (2 bytes) and target (6 bytes). Important: Negative targets
come with 5 digits only (see example no. 3).

Example 1: Read active target (current profile number = 12; target = 12,50)

SOH

Adr

Cmd

EOT

CRC

Transmission

01h

20h

53h

04h

2A

SOH

Adr

Cmd Profile no. = 12

Target = 12,50

EOT

CRC

Response

01h

20h

53h

31h

32

30h

30h

31h

32h

35h

30h

04h

3E

Response upon deletion of all targets:

SOH

Adr

Cmd

Profile no. =

FFh

Target = FFFFFFh

EOT

CRC

Response

01h

20h

53h

3Fh

3F

3Fh

3Fh

3Fh

3Fh

3Fh

3Fh

04h

2Ah


Example 2: Read target of a specific profile (profile number = 17; target = 12,50)

SOH

Adr

Cmd Profile no. = 17 EOT

CRC

Transmission

01h

20h

53h

31h

37h

04h

16h

SOH

Adr

Cmd Profile no. = 17

Target = 12,50

EOT

CRC

Response

01h

20h

53h

31h

37h

30h

30h

31h

32h

35h

30h

04h

BCh


Example 3: Write target of a specific profile (profile number = 17; target = -12,50)

s

SOH

Adr

Cmd Profile no. = 17

Target = -12,50

EOT

CRC

Transmission

01h

20h

53h

31h

37h

2Dh

30h

31h

32h

35h

30h

04h

FBh

SOH

Adr

Cmd Profile no. = 17

Target = -12,50

EOT

CRC

Response

01h

20h

53h

31h

37h

2Dh

30h

31h

32h

35h

30h

04h

FBh

s

Advertising