30" ELECTRIC RANGE INSTALLATION INSTRUCTIONS

Four Conductor Wire Connection to Range

Where local codes does NOT permit connection of the frame
grounding conductor to the neutral wire of the copper power
supply cord (see Figure 7):

1. Remove the screws from the access plate at the lower

right end of the rear cover to expose range terminal
connection block.

2. Remove the grounding strap from the terminal block and

from the appliance frame.

3. Using the nuts supplied with the literature package,

connect the ground wire (green) of the copper power
supply cord to the frame of the appliance with the ground
screw, using the hole in the frame where the ground
strap was removed (see Figure 7).

4. Connect the neutral of the copper power supply cord to

the center silver-colored terminal of the terminal block,
and connect the other wires to the outer terminals. Match
wires and terminals by color (red wires connected to the
right terminal, black wires connected to the left terminal).

5. Replace the terminal cover and replace the screws.

Terminal Block

Silver Colored Terminal

Red
Wire

Neutral
(White Wire)

Ground (Bare
Copper Wire)

To 240 V Receptacle

A User Supplied
Strain-relief Must
Be Installed at
This Location

Black Wire

1 1/8" (2.9cm)
Dia. Direct
Connection
Hole. Punch
Out Knockout for
1 3/8" (3.5cm)
Dia. Cord Kit
Hole.

NOTE: Be sure to remove the
supplied grounding strap.

Figure 7

Three Conductor Wire Connection to
Range

If local codes permit connection of the frame grounding
conductor to the neutral wire of the copper power supply cord
(see Figure 6):

1. Remove the screws from the access plate at the lower

right end of the rear cover to expose range terminal
connection block.

2. Using the nuts supplied in the literature package,

connect the neutral of the copper power supply cord to
the center silver-colored terminal of the terminal block,
and connect the other wires to the outer terminals. Match
wires and terminals by color (red wires connected to the
right terminal, black wires connected to the left terminal)
(see fi gure 6).

3. Replace the terminal cover and replace the screws.

Figure 6

Silver Colored Terminal

1 1/8" (2.9 cm) Dia.
Direct Connection
Hole. Punch Out
Knockout for 1 3/8"
(3.5 cm) Dia. Cord
Kit Hole.

To 240 V
Receptacle

A User Supplied
Strain-relief Must
Be Installed at This
Location.

Black
Wire

Terminal
Block

Cord

Mounting

Plate

Neutral

(White Wire)

Grounding
Strap

Red Wire