30" electric range installation instructions, Checking operation, Before you call for service – FRIGIDAIRE FGEF306TMW User Manual
Page 6
6
30" ELECTRIC RANGE INSTALLATION INSTRUCTIONS
Direct Electrical Connection to the Circuit
Breaker, Fuse Box or Junction Box
If the appliance is connected directly to the circuit breaker,
fuse box or junction box, use fl exible, armored or nonmetallic
sheathed copper cable (with grounding wire). Supply a U.L.
listed strain-relief at each end of the cable. At the appliance
end, the cable goes through the Direct Connection Hole (see
Figure 7) on the Cord Mounting Plate. Wire sizes (copper
wire only) and connections must conform to the rating of the
appliance.
Where local codes permit connecting the appliance-
grounding conductor to the neutral (white) wire (see
Figure 8):
1. Be sure that no power is supplied on the cable from
residence.
2. Follow instructions on previous page for Four Conductor
Wire Connection to Range (Fig. 7).
3. In the circuit breaker, fuse box or junction box (Fig. 8):
a) Connect the green (or bare copper) wire, the white
appliance cable wire, and the neutral (white) wire
together.
b) Connect the 2 black wires together.
c) Connect the 2 red wires together.
Figure 8
3-Wire (Grounded Neutral) Electrical System
(Example: Junction Box)
Cable from Residence
Junction
Box
White Wire
U.L.-listed Conduit
Connector (or CSA
listed)
Cable from
Appliance
Green
(or Bare Copper)
Wire
Red
Wires
Neutral
(white) Wire
Black
Wires
NOTE: Be sure to remove the
supplied grounding strap.
Where local codes DO NOT permit connecting the
appliance-grounding conductor to the neutral (white)
wire, or if connecting to 4-wire electrical system (see
Figure 9):
1. Be sure that no power is supplied on the cable from
residence.
2. Follow instructions on previous page for Four Conductor
Wire Connection to Range (Fig. 7).
3. In the circuit breaker, fuse box or junction box (Fig. 9):
a) Connect the white appliance cable wire to the neutral
(white) wire.
b) Connect the 2 black wires together.
c) Connect the 2 red wires together.
d) Connect the green (or bare copper) grounding wire to
the grounding wire of the circuit breaker, fuse box or
junction box.
NOTE: Be sure to remove the
supplied grounding strap.
U.L.-listed Conduit
Connector (or CSA
listed)
Figure 9 – 4-Wire Electrical System
(Example: Junction Box)
Cable from Residence
Black
Wires
Junction
Box
White Wire
Cable from
Appliance
Green (or Bare
Copper) Wire
Red
Wires
White Wire
Green (or Bare
Copper) Wire
7. Checking Operation
Refer to the Use and Care Guide for operation.
CAUTION
Do not touch cooktop glass or elements.
They may be hot enough to burn you.
Before You Call for Service
Read the Before You Call for Service Checklist and
operating instructions in your Use and Care Guide.
It may save you time and expense. The list includes
common occurrences that are not the result of
defective workmanship or materials in this appliance.