30" GAS RANGE INSTALLATION INSTRUCTIONS

2

Provide an adequate Gas Supply

When shipped from the factory, this unit is designed

to operate on 4" (10,16cm) water column (1.0 kPa)

Natural gas manifold pressure. A convertible pressure

regulator is connected to the range manifold and

MUST be connected in series with the gas supply line.

If LP/Propane conversion kit has been used, follow

instructions provided with the kit for converting the

pressure regulator to LP/Propane use.

Care must be taken during installation of range not to

obstruct the flow of combustion and ventilation air.

For proper operation, the maximum inlet pressure to

the regulator should be no more than 14" (35,56cm)

of water column pressure (3.5 kPa). The inlet

pressure to the regulator must be at least 1" (.25

kPa) greater than the regulator manifold pressure

setting. Examples: If regulator is set for natural gas 4"

(10,16cm) manifold pressure, inlet pressure must be at

3

Seal the openings

Seal any openings in the floor under the range after

gas supply line is installed.

Recommended hole

location for through

the floor gas entry line.

NOTE: The gas entry

line hole can be also

placed anywhere in

the shaded area.

NOTE:

The electric outlet can

be placed anywhere in

the hatched area.

Recommended hole

location for through the

wall gas entry line.

Figure 5a

C. Level and position the range - Slide range to

its final position. Insert the range leveling leg in the

anti-tip bracket. Visually verify if the anti-tip bracket is

engaged. Lower the range by adjusting the 4 leveling legs

alternatively until the range is level. Check if the range

is level by placing a spirit level on the oven rack. Take 2

readings with the spirit level placed diagonally; take a

reading in one direction and then in the other direction.

Level the range if necessary by adjusting the leveling legs.

Figure 3

Figure 4

least 5" (12.60cm); if regulator has been converted for

LP/Propane gas 10" (25,4cm) manifold pressure, inlet

pressure must be at least 11" (27,9cm).

Leak testing of the appliance shall be conducted

according to the instructions in step 4H.

The gas supply line should be ½" or ¾" I.D.