30" gas range installation instructions, Connect the range to the gas supply – FRIGIDAIRE FGGF301DNW User Manual

Page 6

Advertising
background image

6

30" GAS RANGE INSTALLATION INSTRUCTIONS

Figure 5b

Figure 5c

4

Connect the range to the gas supply

Important: Remove all packing material and literature

from range before connecting gas and electrical supply.

Note: To prevent leaks, put pipe joint sealant on all

external pipe threads.

Do not allow regulator to rotate on

pipe when tightening fittings.
Connection to Pressure Regulator

The regulator is already installed on the appliance.

Do not make the connection too tight.

The regulator is die cast. Overtightening may crack the

regulator resulting in a gas leak and possible fire or

explosion.

Do not use a flame to check for gas

leaks.
Checking Manifold Gas Pressure

Disconnect this range and its individual manual shutoff

valve from the gas supply piping system during any

pressure testing of that system at test pressures greater

than 14" water column pressure (approximately ½"

psig).
The appliance must be isolated from the gas supply

piping system by closing its individual manual shutoff

valve during any pressure testing of the gas supply

piping system at test pressures equal to or less than

14" water column pressure (approximately ½" psig).
If it should be necessary to check the manifold gas

pressure, connect manometer (water gauge) or

other pressure device to the top burner right rear

orifice. Using a rubber hose with inside diameter of

approximately ¼" hold tubing down tight over orifice.

Turn burner valve on.
For accurate pressure check have at least two (2)

other top burners burning. Be sure the gas supply

(inlet) pressure is at least one inch above specified

range manifold pressure. The gas supply pressure

should never be over 14" water column. When

properly adjusted for Natural Gas manifold pressure is

4" (For LP/Propane Gas the manifold pressure is 10")

Unit Pressure

Regulator

Flexible

Connector

Unit

Shutoff

Valve

Installed on the unit

Flare

Union

Flare

Union

Manual

Shutoff

Valve

On

Off

GAS FLOW

Note: The purpose of forming the gas flexible

connector is to position it in a way that will not block

the unit or get pinched in it's final position.

If your unit in place is not against the wall as

you wish, check behind the range and place the

gas flexible connector to avoid the range being

blocked or the gas flexible connector being

pinched.

A. Install an external manual gas shut-off valve to

gas supply line in an accessible location outside

of the range. Be sure you know where and how to

shut off the gas supply to the range.

B. Install ½" flare union adapter to unit shut-off valve

using NO MORE THAN 15ft./lbs. of torque.

NOTE: Be sure to stabilize the right side of the

unit shut-off valve with adjustable wrench before

tightening ANY fittings to the unit shut-off valve.

C. Tighten the gas flexible connector and/or

appliance conduit to flare union on the left side

of the unit shut-off valve using NO MORE THAN

15ft./lbs. of torque. Be sure to stabilize the ½"

flare union adapter with an adjustable wrench

before tightening the gas flexible connector and/or

appliance conduit.

D. Install flare union adapter to external shut-off

valve.

E. Attach the gas flexible connector with the flare

union on shut-off valve.

F. Make sure both shut-off valves are in the "ON"

position.

G. Form the gas flexible connector as shown on figure

5c. This will prevent the flexible connector from

pinching or blocking the unit when you will push it

back in its final position.

H. Check for leaks. Turn the gas supply on to the range

and use a liquid leak detector (or soap and water)

at all joints and conduits to check for leaks in the

system.

Advertising