Chapter 5: Installation

50

HSIM-W6 User’s Guide

Maintain a temperature of between 5

°

C (41

°

F) and 40

°

C (104

°

F) at the installation site with

fluctuations of less than 10

°

C (50

°

F) per hour.

Maintain a two-inch clearance for each side and the back of the device for adequate ventilation.

Installing Interface Modules

Depending on your specific application, install Cableton Systems WAN Port Interface Modules
(WPIMs) and the CSX-COMP/ENCR into the HSIM-W6 before proceeding with the installation
of your HSIM-W6. Refer to the

Installing WAN Port Interface Modules (WPIMs)

and

CSX-COMP/ENCR Installation

sections within this chapter for installation instructions.

Installing WAN Port Interface Modules (WPIMs)

To install a WPIM into the HSIM-W6, refer to

Figure 11

and

Figure 12

and complete the

following steps:

1.

Attach the antistatic wrist strap to your wrist (refer to the instructions on the antistatic wrist
strap package).

2.

Remove and save the three screws from the WPIM standoffs (see Figure 2). Remove the WPIM
coverplate.

!

CAUTION

The WPIMs and CSX-COMP/ENCR for the HSIM-W6 are sensitive to static
discharges. Use a grounding strap and observe all static precautions during
installation. Failure to do so could result in damage to the WPIMs, CSXCOMP/ENCR,
and the HSIM-W6.

NOTE

The HSIM-W6 must have at least one EPIM and one WPIM installed before you can
begin configuring the device.

NOTE

Both WAN ports can be populated. However, if only a single WPIM is used to
communicate and configure your HSIM-W6, WIDE AREA 1 port must have a WPIM
installed.