7 Slide the system in and out of the rack to verify that the cables are routed correctly and do not bind,

stretch, or interfere with the movement of the cable-management arm. Adjust the cable positioning
inside the cable-management arm as needed.

NOTE:

If you pull the system out to its furthest extension, the slide assemblies will lock in the extended

position. To release the lock, press the slide release latch on the side of each slide and then slide the system
into the rack.

8 When you are satisfied that the cables are routed correctly, push the system fully into the rack.

Attaching the Cable-Management Arm Ramp Assembly

The cable-management arm ramp assembly guides the cable-management arm into a stable,
level position. To attach the cable-management arm ramp assembly:

1 Select only one ramp assembly, depending on the orientation of the cable-management arm.

a

If the cable-management arm is attached on the right side of the rack (as shown in Figure 1-11),
attach the left cable-management arm ramp assembly to the rack (see Figure 1-10).

b

If the cable-management arm is attached on the left side of the rack, attach the right cable-
management arm ramp assembly to the rack (see Figure 1-10).

CAUTION:

The cable-management arm ramp assembly must be installed to prevent long-term sagging

of the cable-management arm.

NOTE:

Ensure that you use the cable-management arm ramp assembly with the metal ramp facing toward

the center of the rack (see Figure 1-10).

NOTE:

The orientation shown in Figure 1-10

presumes you are facing the back of the system.

Figure 1-10.

Orientation for the Left or Right Cable-Management Arm Ramp Assembly

1

left cable-management arm
ramp assembly

2

right cable-management arm
ramp assembly

3

metal ramp

1

2

3