Stardance natural vent gas heater – Vermont Casting SNV30 User Manual

Page 17

Advertising
background image

17

Stardance Natural Vent Gas Heater

20007067

FC107

SIT820

valve conversion

10/03

A

B

C

OFF

PIL

OT

O

Fig. 28 Remove mounting screws, pressure regulator tower
and spring and diaphragm assembly.

FC107

D

E

F

FC108

SIT

regulator

conversion

10/03

OFF

PIL

OT

O

FC108

Fig. 29 Replace regulator.

3. Install the enclosed conversion label (F) to the valve

body where it can easily be seen. (Fig. 29)

Pilot Orifice Conversion
14. Locate pilot. (Fig. 26)
15. Replace pilot orifice.

Remove pilot hood by lifting up. (Fig. 30) NOTE:
It is not necessary to remove the pilot tube for
conversion.

Remove pilot orifice with allen wrench. (Fig. 31)

Install the conversion orifice.

Reinstall pilot hood. Be sure to align hood with
index tab.

16. Adjust air shutter on the burner. The air shutter is

located on the bottom of the burner on the left. (Fig.
32) Loosen the two nuts holding the shutter in place.
On natural gas units, the shutter is shipped fully
closed. To convert to LP, reset the shutter as speci-
fied in Table 2. (Fig. 33) On propane unit the shutter

CO105a

gas conversion

Pilot

1/28/00 djt

Pilot Hood

Pilot

Bracket

CO105a

Fig. 30 Remove pilot hood.

CO106a

DV360/580

Gas Conversion

Pilot2

1/28/00 djt

Index Tab

Snap Ring

Allen Wrench

CO106a

Fig. 31 Remove pilot orifice.

is set at 1/8” or 3/8” opening depending on rating
plate serial number. To convert to natural gas, the
shutter should be set to fully closed. Refasten the
two nuts. (Fig. 33)

NOTE: Be sure burner leg remains at a 90° angle to

firebox base after conversion.

ST785

SNV

air shutter

lp gas position

11/20/03 djt

3/8"

Air Shutter

(LP Position)

ST785

Fig. 32 LP air shutter settings.

ST718

SNV

air shutter

natural gas position

8/23/02 djt

Burner

Air Shutter

ST784

Fig. 33 Natural gas air shutter setting.

Rear

Injector

Air Inlet

Covered

Front Injector

Air Inlet