Cm2c40 hardware reference, Motor control hardware information – Chief Manufacturing Automated Flat Panel Ceiling Lift CM2C40 User Manual

Page 22

Advertising
background image

CM2C40

Installation Instructions

22

CM2C40 Hardware Reference

Motor Control Hardware Information

(See figure 31)

RS485 Network Programmable Paramaters and Status Bit Assignments

RS485 Network Programmable Parameters

Parameter

Identifier

Name

Range

Factory Default

Units

0 Custom Code

1-32687

0

-

1 Maximum Movement Time

100-6000

3100

0.01 sec

2 Extend Speed

1-100

100

%

3 Retract Speed

1-100

100

%

4 Ramp UP Time

10-100

100

0.01 sec

5 Ramp DOWN Time

10-100

100

0.01 sec

6 Show Extend Delay

31-300

100

1 sec

7 Show Retract Delay

31-300

100

1 sec

RS485 Network Status Bit Assignments

Bit

Name

Bit Location

0 At Home Position

- - - - - - - - - - - - - - - X

1 Move in Progress

- - - - - - - - - - - - - - X -

2 Network Operation in Progress

- - - - - - - - - - - - - X - -

3 Parameter Write Operations Enabled

- - - - - - - - - - - - X - - -

4 Network Command Error

- - - - - - - - - - - X - - - -

8 At Extend Limit

- - - - - - - X - - - - - - - -

9 At Retract Limit

- - - - - - X - - - - - - - - -

Advertising