Installation Instructions

CM2C40

27

Connector and Switch Assignments

All Dipswitches are in the "OFF" position when shipped from factory.

SW1

Switch 1

IR

Switch 2

IR

Switch 3

IR

Switch 4

Not Used

Switch 5

Not Used

Switch 6

485 Address

Switch 7

485 Address

Switch 8

485 Address

IR System Code Select Logic

Switch Settings (Sw 1-3)

Select 2

Select 1

Select 0

IR System Code

OFF

OFF

OFF

6E

OFF

OFF

ON

E1

OFF

ON

OFF

E2

OFF

ON

ON

E3

ON

OFF

OFF

E4

ON

OFF

ON

E5

ON

ON

OFF

E6

ON

ON

ON

E7

RS485 Address Select Logic

Switch Settings (Sw 6-8)

Select 2

Select 1

Select 0

RS485 Network

Address

OFF

OFF

OFF

0

OFF

OFF

ON

1

OFF

ON

OFF

2

OFF

ON

ON

3

ON

OFF

OFF

4

ON

OFF

ON

5

ON

ON

OFF

6

ON

ON

ON

7