Installation Instructions

CM2C40

5

INSTALLATION REQUIREMENTS

The CM2C40 has been designed to be mounted either hanging
from an overhead structure or mounted to existing stud wall
structures.

WARNING:

IMPROPER INSTALLATION CAN LEAD TO

LIFT TIPPING CAUSING SEVERE PERSONAL INJURY OR
DAMAGE TO EQUIPMENT! It is the installers responsibility
to make certain the structure to which the lift is being
mounted is capable of supporting 4 times the weight of the lift
and all attached equipment.

Power Requirements and Wiring

The CM2C40 requires 120VAC (220/240VAC 50 Hz for
European installations) power to operate.

A 6’ long power cable is provided with the mount.

INSTALLATION

Pre-Installation Configuration and Adjustments

Prior to being installed, the CM2C40 requires the configuration
of the mount for display, cable installation and routing, and the
rough adjustment of the top cover mounting bracket.

To prepare the CM2C40 for Installation:

1.

Remove mount from box.

2.

Remove two wooden supports from under box.

3.

Lay two wooden supports on floor and mount CM2C40C40
to supports using four 5/16’ flat washers and four
5/16’ x 2 1/2" lag bolts (hardware provided). (See figure 1)

Figure 1

Configuring the Mount for the Display

Prior to installation, the CM2C40 needs to be configured for the
size of the display being used.

To prepare the CM2C40 for the display being installed:

1.

Install interface bracket or mounting buttons to display
following the instructions provided with bracket.

2.

Measure the distance from the center of a bottom mounting
button to the lowest point of the display.

3.

Record measurement.

Figure 2

IMPORTANT ! :

If the dimension taken in figure 2 is greater

than 16" (406mm), the faceplate will need to be adjusted
before mounting the display. If the dimension taken in figure 2
is less than 16" (406mm) proceed to Cable installation and
Routing
below.

Adjusting Faceplate Location
The CM2C40 is designed to allow up to 6.5" of adjustment. Up
to 2" by adjusting the faceplate location on the faceplate
mounting bracket, and up to an additional 4.5" by adjusting the
faceplate mounting bracket.

Subtract 16" from the dimension determined in figure 2. The
difference between the two is the total amount of adjustment
the faceplate will require.

If 2" or less faceplate adjustment is required proceed to step 5.
If more than 2" of faceplate adjustment is required proceed to
step 8.

NOTE:

Depending upon the amount of faceplate adjustment

required, it maybe necessary to adjust both the
faceplate and faceplate mounting bracket.

If 2" or less faceplate adjustment is required:

4.

Install IR receiver. (See figure 3)

5.

Plug appropriate power cord into mount and power source.

6.

Using the remote control, raise lift until locknuts on back
side of faceplate can be accessed. (See figure 3)

WARNING:

PINCH HAZARD! FINGERS OR HANDS

BETWEEN MOVING PARTS CAN LEAD TO SEVERE
PERSONAL INJURY! Keep fingers and hands away from
mount when operating.

Lag Bolt

Flat Washer

Wooden Supports

(from bottom of box)

2

1

Example:

Dimension from step 2 = 19.5"

19.5" - 16" = 3.5" (Amount of faceplate adjustment required)